Search
Close this search box.

Home

How To Check A Pressure Switch On A Furnace?

Is your furnace acting up? Is it turning off unexpectedly, or maybe it’s not heating your home like it used to? One of the culprits could be a faulty pressure switch for furnace. Don’t worry if you’re scratching your head wondering what that even is. We’re here to break it down for you in simple terms.

In this post, we’ll explain exactly what a furnace pressure switch does, why it’s important, and what happens when it goes bad. So, let’s get started!

What Is A Furnace Pressure Switch?

A furnace pressure switch is a safety device that ensures proper airflow in your furnace. It prevents dangerous fumes from entering your home. It’s designed to shut down the furnace if it detects negative pressure or a lack of airflow. This helps prevent dangerous situations like back drafting, where harmful gases can be reintroduced into your home.

Pressure switch on a furnace ensures safe operation by measuring the air pressure passing through the heat exchanger. This switch is crucial because it confirms whether the furnace’s fan or draft inducer is working correctly.

How Does Pressure Switch On A Gas Furnace Work?

Furnace Pressure Switch

The pressure switch detects air pressure against a diaphragm inside the switch. If the pressure is within the acceptable range, the switch allows the furnace to operate normally. However, if the pressure is too low or too high, it signals the furnace control board to stop the heating process. This prevents the system from running without proper ventilation or airflow, which could lead to overheating or the release of harmful gases like carbon monoxide.

Why Does Furnace Pressure Switch Fail?

Furnace pressure switches can fail for various reasons, affecting your heating system’s safety and efficiency. Here are some common causes of failure:

  • Obstruction in the Venting System: Debris or snow can block the venting system, altering pressure levels and causing switch malfunctions.
  • Draft Inducer Motor Issues: A failing draft inducer motor may not manage air pressure effectively, leading to improper switch activation and furnace shutdowns.
  • Hose Damage: Cracks, holes, or loose connections in the hose linking the pressure switch to the draft inducer can result in inaccurate pressure readings.
  • Condensation Drainage Problems: In condensing furnaces, issues with condensation drainage can falsely signal pressure problems.
  • Wear and Tear of the Switch: Over time, the diaphragm within the switch can wear out, corrode, or become stiff, affecting its functionality.
  • Damage to the Diaphragm: Holes, tears, or other physical damage to the diaphragm can prevent it from measuring pressure accurately.
  • Dust and Dirt Buildup: Accumulation of dust or dirt can cause the switch to jam or stick, leading to furnace cycling issues.
  • Aging Components: Older switches may provide inaccurate readings due to general wear, affecting furnace operation.
  • Improper Installation: Incorrect installation or calibration of the pressure switch can lead to repeated failures.

How To Check A Pressure Switch On A Furnace?

Testing furnace pressure switch ensures it works properly, maintaining your heating system’s safety and efficiency. Here’s an enhanced guide to perform a thorough test.

1. Turn Off the Power: Always start by turning off the power to the furnace to ensure safety.

2. Locate and Access the Pressure Switch: Find the pressure switch, usually near the draft inducer motor. Refer to your furnace’s schematic or manual for the exact location.

3. Inspect Hoses for Damage: Check the hoses connected to the pressure switch for cracks, clogs, or damage. A compromised hose can affect pressure readings and cause the switch to fail.

4. Disconnect the Tubes: Gently disconnect the tubes from the switch. This prevents any pressure changes from affecting your readings during electrical tests.

5. Test Continuity: Use a multimeter set to continuity mode. Connect the meter leads to the switch terminals. A properly functioning switch should show zero or near-zero resistance when the furnace is calling for heat (switch closed).

6. Voltage Test: Measure the voltage between each terminal and ground using a voltmeter. Proper functioning should show a reading between 24 and 28 volts DC when the furnace is operating. This confirms the switch is receiving the correct operating voltage.

7. Simulate Pressure: Reconnect the tubes and gently blow into the pressure switch to simulate the inducer motor’s pressure. Monitor the multimeter for changes, ensuring the switch activates (closes) under pressure.

8. Repeat and Verify: Conduct each test multiple times to confirm consistency in the switch’s response, highlighting any intermittent issues.

9. Reassemble and Test Operation: After testing, securely reconnect all components, turn the power back on, and observe the startup sequence to ensure the furnace operates correctly.

Types Of Pressure Switches For Furnace

Pressure switch for furnace comes in different types, each designed for specific heating systems and safety needs. Here are the most common types:

1. Single-Stage Conventional Furnace

A single-stage conventional furnace uses one hose that connects the draft inducer fan to the pressure switch. The pressure switch ensures the fan creates enough pressure to safely exhaust gases through the flue.

2. Single-Stage Condensing Furnace

A single-stage condensing furnace uses two hoses on the pressure switch. One hose measures the pressure at the draft inducer to ensure proper operation. The second hose senses the venting pressure at the condensate collector box, managing the condensation process in high-efficiency furnaces.

3. Two-Stage Furnace

Two-stage furnaces may have two pressure switches, one for each heating stage. These switches ensure efficient operation at different stages, whether at full capacity during colder times or reduced capacity when less heat is needed.

4. Modulating Furnace

Modulating furnaces is the most advanced, adjusting the heating output in precise increments. Use up to three pressure switches to finely monitor and adjust the system’s operation for optimal performance and efficiency.

How To Replace A Furnace Pressure Switch?

Replacing a faulty furnace pressure switch is manageable with these step-by-step instructions:

  • Power off the furnace completely to avoid electrical hazards.
  • Locate the pressure switch near the draft inducer motor, connected by small hoses.
  • Take a photo or note the wire connections and hose placements for accurate reconnection.
  • Gently disconnect the wires and hoses from the old pressure switch to avoid damage.
  • Unscrew or unclip the old pressure switch from its mounting bracket.
  • Securely mount the new pressure switch on the bracket.
  • Reconnect the hoses and wires to the new switch using your notes or photos.
  • Ensure all hose connections are tight and leak-free before powering on.
  • Turn the power back on and start the furnace, observing the startup sequence to ensure the new switch works correctly.

Also Check:

FAQs:

How can I fix a pressure switch that is stuck open?

A stuck open pressure switch can stop your appliance from working. First, check the vent for blockages and inspect the pressure switch hose for damage. Clean the switch and test it with a multimeter. If the switch is faulty, replace it. Consult a professional if you’re unsure.

Is it possible to operate a furnace without a pressure switch?

No, it is not safe or recommended to operate a furnace without a pressure switch. This switch is a critical safety feature that ensures the furnace operates at the correct pressure levels, preventing potential hazards like gas leaks or fire. It’s essential for maintaining safe and efficient operation.

Why is a furnace pressure switch important?

A furnace pressure switch is crucial for safety. It helps prevent carbon monoxide poisoning, fires, and other hazards caused by improper ventilation.

How often should a furnace pressure switch be replaced?

There’s no specific timeframe for replacing a pressure switch. However, if it’s malfunctioning or the furnace is experiencing frequent issues, it might need to be replaced.

Conclusion

The furnace pressure switch is crucial for the safety and efficiency of your heating system. It monitors airflow and pressure, preventing operation in unsafe conditions. Regular maintenance of the pressure switch is essential to avoid hazards like gas leaks or fire. Keeping this component in good condition ensures your furnace operates safely and effectively during the colder months.

Leave a Reply

Your email address will not be published. Required fields are marked *